Win bids and build faster with Electrical BIM Modelling & Drawings Services aligned to U.S. codes and GC expectations. We deliver Revit electrical modeling, shop drawings, clash-free coordination, and prefab-ready outputs. For Electrical Contractors and General Contractors who want speed, accuracy, and predictable costs. Request a fixed bid or upload markups for a 24-hour estimate.
Who Uses Electrical BIM Modelling & Drawings Services in the USA (ECs, GCs, Prefab Teams)
Electrical Contractors (ECs).
Ideal for tenant improvements, core & shell, healthcare, industrial, hospitality, and data centers. You get coordinated conduit and cable tray routing, accurate quantities, and schedules you can build from—reducing RFIs and night-work conflicts.
General Contractors (GCs).
Gain trade coordination clarity, enforce the BEP, and reduce rework. Receive consistent naming, shared parameters, and trackable issue logs that keep weekly coordination meetings focused and efficient.
Design-Assist & Prefab Teams.
Pull us in from DD→CD→shops. We model to LOD 350/400, issue spool drawings, hanger/insert plans, and point layout CSVs to accelerate field layout and fabrication.
Scope of Electrical BIM Modelling & Drawings Services: What’s Included and How You Receive It
Core Modeling and Sheet Set (RVT, PDF, DWG)
- Revit electrical model built to the agreed LOD 300/350/400—fit for coordination or fabrication.
- Plans, sections, and details with U.S. sheet naming, title block, and revision standards.
- Legends and schedules for devices/equipment, panel boards, and feeders—exportable to CSV/XLSX for estimation.
Electrical Shop Drawings (Revit) with One-Lines and Panel Schedules
- Electrical shop drawings (PDF/DWG) produced directly from the model for submittals and installation.
- One-line diagrams and panel schedules synchronized with model parameters so labels, circuits, and loads stay consistent through revisions.
Coordination and Data for GC Sign-Off (Navisworks)
- Navisworks coordination models and clash reports (PDF/HTML) with issue IDs, priorities (hard/soft), ownership, and status.
- BOM/quantity takeoffs for conduit, cable tray, hangers, supports, and typical fittings—formatted for procurement and prefab kits.
Conduit BIM, Cable Tray BIM, and Field-Ready Outputs
- Clearance-aware conduit and cable tray BIM with routing logic that respects access, working space, and tray fill.
- Hanger & insert plans with grid references and elevations; consistent annotations that installers trust.
- Point layout exports (CSV) ready for total stations (sleeves, anchors, penetrations, and critical points).
As-Builts and Record Drawings (Project Closeout)
- Revision-controlled as-built electrical BIM and updated sheet sets based on field markups, RFIs, and change orders.
- Final record drawings in PDF/DWG/RVT that speed closeout and future maintenance.
U.S. Standards and Compliance for Electrical BIM (NEC/NFPA 70, AHJ, LOD, BEP)
NEC/NFPA 70 alignment.
We reference U.S. electrical code for working clearances, labeling, conductor considerations, raceway fill, and equipment access—so your submittals align with AHJ expectations.
AHJ and GC conventions.
Sheet naming, annotation style, and revision control match U.S. norms. Local AHJ notes are captured early to limit resubmittals.
LOD clarity.
LOD 300: design-intent; sufficient for pricing and early coordination. LOD 350: coordinated systems with supports/penetrations; ready for sign-off. LOD 400: fabrication detail; prefab spool drawings produced reliably.
BEP alignment.
We follow the BIM Execution Plan: coordinates, levels/grids, file exchanges, review cadence, model deliverables, and approval gates—so every trade stays synchronized.
Electrical BIM Workflow: Step-by-Step Process You Can Track
1) Intake & Scope Definition
Share PDFs/DWGs/RVT, redlines, device schedules, one-lines, BEP, and the LOD target. We define packages (permit, shops, as-builts), access to CDE, and milestone dates.
2) Revit Model Setup & Hygiene
Establish project coordinates, levels/grids, shared parameters, view templates, and worksets. Confirm naming conventions and view filters for consistent tags and schedules.
3) Electrical Routing & Placement (Revit)
Execute Revit electrical modeling for conduit, cable tray, devices, equipment, and penetrations. Validate access and clearances for maintainability and install safety.
4) Navisworks Coordination & Clash Resolution
Export NWC/NWD, run clash tests against MEP/structure/architecture. Classify hard vs soft clashes, propose reroutes, and assign owners. Track decisions in logs.
5) Design Reviews & Revisions
Incorporate comments, update tags and schedules, and maintain a versioned change log. Keep coordination meetings short by sharing pre-meeting snapshots.
6) QA/QC Gate—Pre-Issue Checks
Verify dimensions, tray fill, device IDs, feeder sizes, panel schedules, and sheet set completeness. Confirm that metadata syncs to schedules and export files.
7) Issue for Review (IFR) and AHJ Pre-Check
Publish coordinated sets (PDF/DWG), model exports (RVT/NWC), and a clash report summary. Resolve remaining comments with a 24–48-hour response SLA.
8) Final IFC / Permit Set and Closeout
Issue IFC or permit-ready documents. Capture field markups, RFIs, and change orders into as-builts and produce the record set for handover.
How Long Electrical BIM Modelling & Drawings Services Take (Turnaround & SLAs)
| Project Scope | Typical Duration | Review Rounds | What to Expect |
|---|---|---|---|
| Small TI (≤20k sf) | 5–10 business days | 1–2 | Focused routing; quick clash cycles |
| Mid-size (20k–150k sf) | 2–5 weeks | 2–3 | Multiple floors; higher device density |
| Complex (Hospitals/Industrial/Data) | Phased plan | 3–5+ | Specialized rooms; strict clearances |
Response SLAs
Issue log responses within 24–48 hours; same-day for critical blockers. U.S. morning overlap standard; extended overlap available. Expedited windows available for limited scopes.
How Much Electrical BIM Modelling & Drawings Services Cost (Pricing & Engagement Models)
| Package | LOD | Typical Range (USD) | What’s Included |
|---|---|---|---|
| TI / Small Core & Shell | 300–350 | $3,500–$12,000 | Revit model + sheets, clash report, basic schedules |
| Mid-Rise / Multi-Family | 350 | $12,000–$35,000 | Full coordination set, risers, one-lines, panel schedules |
| Healthcare / Industrial / Data | 350–400 | $35,000+ | Complex rooms, supports, spool sets, QA gates |
What Drives Price Up or Down
LOD target; floor count and area; device/equipment density; clash complexity and number of coordination rounds; prefab scope (spools, hanger/insert plans); expedite requirements.
Engagement Options
Fixed Bid per Package; Dedicated Team / Monthly Retainer; Hybrid Design-Assist → Shops.
Prefabrication-Ready Electrical BIM: Spool Drawings, Hanger Plans, Labels, and BOMs
Prefab Deliverables
Prefab spool drawings with labeling/QR, assembly notes, and cutting lists. Hanger & insert plans with grid and elevation controls. BOM exports and kit-of-parts strategies. Point layout CSVs for total stations. Rack strategies for congested ceilings.
Electrical BIM Quality Assurance: The Pre-Issue Checklist We Run on Every Set
Checklist Items
Dimensions & clearances; device/equipment IDs and circuits; panel schedules and one-lines synced; tray fill and conduit bundling; sheet set integrity; model hygiene; Navisworks coordination status and open issue log.
Case Study Snapshot: Electrical BIM for Healthcare Fit-Out (LOD 350)
Fast Facts
Scope: 120k sf healthcare fit-out; LOD 350; coordinated shop drawings; hanger/insert plans; BOM + point layout CSV.
Timeline: 4 weeks to IFR; 2 coordination rounds; IFC at week 6.
Outcome: 92% clash reduction before field, 18% prefab time savings, 0 AHJ resubmittals for the electrical set.
How Built In BIM Helps You Deliver Electrical BIM Faster (and Safer)
Built In BIM plugs into your workflow to produce NEC/NFPA-aligned electrical models, shop drawings, and prefab outputs without slowing the schedule.
What You Get
- Outcome-first modeling. Revit electrical modeling to LOD 300/350/400 with one-lines, panel schedules, risers, and coordinated conduit/cable tray.
- Clash-free coordination. Structured Navisworks coordination with hard/soft clash buckets, owners, and timestamps—so meetings stay short and decisions stick.
- Prefab-ready deliverables. Spool drawings, hanger/insert plans, BOM exports, and point layout CSVs for total stations—accelerate fabrication and install.
- AHJ & GC alignment. U.S. sheet naming, revision control, and BEP compliance reduce resubmittals and RFI churn.
- Predictable timelines & costs. Fixed-bid options with clear inclusions, plus 24–48 hr response SLAs for comments and redlines.
- Clean handover. Record-accurate as-builts and model hygiene (parameters, worksets, view templates) that your team can maintain.
Get your BIM project price instantly.
FAQs: Electrical BIM Modelling & Drawings Services for ECs and GCs
What files do you need to start electrical BIM?
PDFs or DWGs, any existing RVTs, redlines/markups, device schedules, one-line diagrams, and the BEP/coordination protocol. A 15-minute scoping call aligns LOD, deliverables, and dates.
What’s included in Electrical BIM Modelling & Drawings Services?
A coordinated Revit model, shop drawings (PDF/DWG), clash reports, one-lines, panel schedules, and—if scoped—prefab spools, hanger/insert plans, BOMs, point layout CSVs, and as-builts.
Do you follow NEC/NFPA and support AHJ comments?
Yes. We align with NEC/NFPA 70 references and typical AHJ notes, plus U.S. sheet naming and annotation standards to reduce resubmittals.
How do revisions and coordination rounds work in Navisworks?
We plan the rounds in the BEP. Clashes are tagged by priority with owners and due dates. Turnarounds are 24–48 hours, with same-day responses for blockers.
Can you deliver permit-ready/IFC sets and prefab spool drawings?
Yes. We issue IFR/IFC packages and produce prefab spool drawings, hanger/insert plans, and point layout exports where included.
How is pricing calculated—and what can change mid-project?
Pricing depends on LOD, area, device density, and clash complexity. Mid-project changes usually reflect scope expansions or compressed timelines.
Who owns the model and drawings?
Ownership transfers per contract upon final payment. We retain working files for warranty/support unless otherwise requested.
Do you offer expedited delivery (72 hours)?
Yes. For narrow scopes we provide 72-hour turnarounds with pre-agreed assumptions to protect quality. Reserve expedite slots early.